Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
apc network management card vulnerabilities and exploits
(subscribe to this query)
4.3
CVSSv2
CVE-2009-1798
Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote malicious users to inject arbitrary web script or HTML via unsp...
Apc Network Management Card
Apc Switched Rack Pdu
1 EDB exploit
4.3
CVSSv2
CVE-2009-4406
Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote malicious users to inject arbitrary web script or HTML via the login_usern...
Apc Ap7932 B2 Firmware 3.3.3
Apc Ap7932 B2 Firmware 3.7.0
Apc Ap7932 B2
6.8
CVSSv2
CVE-2009-1797
Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote malicious users to hijack the authentication of (1) admi...
Apc Network Management Card
Apc Switched Rack Pdu
5
CVSSv2
CVE-2018-7820
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
Schneider-electric Ap9630 Firmware
Schneider-electric Smart-ups Srt 5kva Firmware
Schneider-electric Ap9631 Firmware
Schneider-electric Ap9635 Firmware
5
CVSSv2
CVE-2021-22815
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
4.3
CVSSv2
CVE-2021-22811
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Un...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
4.3
CVSSv2
CVE-2021-22812
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Ph...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
4.3
CVSSv2
CVE-2021-22813
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit poli...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
4.3
CVSSv2
CVE-2021-22814
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) u...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
4.3
CVSSv2
CVE-2021-22810
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete pol...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2022-48700
CVE-2022-48689
CVE-2024-27956
CVE-2023-6363
SQL
NULL pointer dereference
CVE-2023-41830
CVE-2015-2051
arbitrary
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
NEXT »